Amalia, - and Vinifera, Vitis (2015) PERENCANAAN GEDUNG KANTOR DINAS KEHUTANAN KABUPATEN MUSI BANYUASIN. Other thesis, Politeknik Negeri Sriwijaya.
|
Text (COVER dan DAFTAR PUSTAKA)
PERLENGKAPAN.pdf Download (473kB) | Preview |
|
|
Text (BAB I PENDAHULUAN)
BAB 1 OKE.pdf Download (97kB) | Preview |
|
|
Text (BAB II TINJAUAN PUSTAKA)
BAB 2 OKE.pdf Download (1MB) | Preview |
|
![]() |
Text (BAB III PERHITUNGAN KONSTRUKSI)
BAB 3 OKE.pdf Restricted to Repository staff only Download (2MB) |
|
![]() |
Text (BAB IV PENGELOLAAN PROYEK)
BAB 4 OKE.pdf Restricted to Repository staff only Download (285kB) |
|
|
Text (BAB V PENUTUP)
BAB 5 OKE.pdf Download (222kB) | Preview |
Abstract
When the economy is growing rapidly in Musi Banyuasin district, so it would be goverment of district to give his attention of infrastructure for Musi Banyuasn development in natural resource it is office of forestry department that has a function to manages natural resources in there. Forestry department is located in Sekayu Musi Banyuasin on an area of 1778 m² with planning consultan from CV. Mustika Jaya Konsultam Palembang. This building using concrete stucture and pile foundation is guided by the basic rules of SNI 03-1729-2002 as well as other books related to planning of reinforced concrete structure. From the building structure design of the forestry office is used square pile foundation sized (20 x20) cm with a depth of 12 m, the dimensions of the column size (40 x40) cm and using a 16mm diameter of rebar and thickness of the floor plate is 120 mm. Base on calculations it can be concluded that the structure is stable and secure
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | This building using concrete stucture and pile foundation is guided by the basic rules of SNI 03-1729-2002 as well as other books related to planning of reinforced concrete structure. From the building structure design of the forestry office is used square pile foundation sized (20 x20) cm with a depth of 12 m, the dimensions of the column size (40 x40) cm and using a 16mm diameter of rebar and thickness of the floor plate is 120 mm. Base on calculations it can be concluded that the structure is stable and secure |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Civil Engineering > Undergraduate Theses |