PROTOTYPE POWER GENERATION (Interpretasi Saturated Burning Zone ditinjau dari Flame Temperatur pada Steam Power Generation Closed Cycle System)

Maulia, Mutiara (2015) PROTOTYPE POWER GENERATION (Interpretasi Saturated Burning Zone ditinjau dari Flame Temperatur pada Steam Power Generation Closed Cycle System). Other thesis, Politeknik Negeri Sriwijaya.

[img]
Preview
Text (COVER)
COVER.pdf

Download (429kB) | Preview
[img]
Preview
Text (BAB I PENDAHULUAN)
BAB I.pdf

Download (99kB) | Preview
[img]
Preview
Text (BAB II TINJAUAN PUSTAKA)
BAB II.pdf

Download (658kB) | Preview
[img] Text (BAB III METODELOGI PENELITIAN)
BAB III.pdf
Restricted to Repository staff only

Download (205kB)
[img] Text (BAB IV HASIL DAN PEMBAHASAN)
BAB IV.pdf
Restricted to Repository staff only

Download (295kB)
[img]
Preview
Text (BAB V KESIMPULAN DAN SARAN)
BAB V.pdf

Download (85kB) | Preview

Abstract

Steam Power Generation is a power plant that utilizes the heat energy of the steam to turn a turbine so that it can be used to generate electric power through the generator. The chemical reaction of burning occurs through an oxidation process of carbon compounds , hydrogen and sulfur that are present in the fuel generally produce flame. The purpose of this undergraduate thesis is to determine the optimum operating conditions in terms of temperature of a flame of fire ( Flame temperature ) in the combustion chamber ( the burning zone ), loss of heat flue gas and efficiency of boiler type fire tube boiler. The procedure is done with fixed parameters, namely the volume of diesel fuel used by as much as 4 liters, while the independent parameter, i.e. the fuel with the air presure variation 4, 5, 6, and 7 Bar. Based on the results of the calculation of the theoritical flame temperature solar incentives that are in the range 481,62o C – 527,21o C whereas in actual using thermo gun obtained temperature flame 470o C – 530o C. From research conducted fuel optimum air pressure is 5 Bar with temperature flames of 527,21o C generating efficiency of 60,85%. Kata kunci : Fire Tube Boiler, Flame Temperature , Burning Zone, efficiency

Item Type: Thesis (Other)
Uncontrolled Keywords: Fire Tube Boiler, Flame Temperature , Burning Zone, efficiency
Subjects: T Technology > TP Chemical technology
Divisions: Chemical Engineering > Undergraduate Theses
Depositing User: Mrs Trisni Handayani
Date Deposited: 23 Nov 2015 01:52
Last Modified: 23 Nov 2015 01:52
URI: http://eprints.polsri.ac.id/id/eprint/1932