SADEWO, TIRAS ARI (2016) PENGATURAN TEGANGAN SISI SEKUNDER PADA TRANSFORMATOR DAYA I 60 MVA 150/20 kV DENGAN PENGUBAH TAP BERBEBANDI GARDU INDUK KERAMASAN PT. PLN. Other thesis, POLITEKNIK NEGERI SRIWIJAYA.
|
Text
1.COVER.pdf Download (309kB) | Preview |
|
|
Text (BAB I Pendahuluan)
2.BAB I.pdf Download (302kB) | Preview |
|
|
Text (BAB II Tinjauan Pustaka)
3.BAB II.pdf Download (1MB) | Preview |
|
![]() |
Text (BAB III Metode Penelitan)
4.BAB III.pdf Restricted to Repository staff only Download (580kB) |
|
![]() |
Text (BAB IV Hasil dan Pembahasan)
5.BAB IV.pdf Restricted to Repository staff only Download (1MB) |
|
|
Text (BAB V Kesimpulan dan Saran)
6.BAB V.pdf Download (208kB) | Preview |
|
|
Text
7.DAFTAR PUSTAKA.pdf Download (7kB) | Preview |
Abstract
Continuity and reliability of electric power distribution can be achieved when the power system that has a stable voltage. Stable voltage depends on the reliability of the power system that starts from the plant to the load. Power transformer in the substation serves to transform the electric power to the load. Because the primary side voltage and load are always changing making the secondary side voltage is not stable and therefore is used On Load Tap Changer. On Load Tap Changer serves to stabilize the secondary side voltage to match the nominal specified by changing the transformer turns ratio without deciding distribution of electrical energy.Tap positions can be determined by calculating the ratio of the voltage transformer. Tap position in theKeramasan Substation currently on the 8th position with a ratio value of 7.5 (normal state). According to the IEC regulations voltage secondary side of the transformer must have a value of + 2.5%. The situation is, the secondary side voltage at Transformer I in Keramasan Substation should be at 20,5 kV but the reality on the clock 09:00 to 11:00 has a voltage value of the secondary side of -0,5% or 19,9 kV.Means the secondary side voltage at Transformer I in Keramasan Substation did not reach the standard IEC.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | gardu induk, transformator, on load tap changer, pengubah tap berbeban, tegangan sisi sekunder |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering > Undergraduate Theses |
Depositing User: | Mrs Trisni Handayani |
Date Deposited: | 25 Apr 2017 03:39 |
Last Modified: | 25 Apr 2017 03:39 |
URI: | http://eprints.polsri.ac.id/id/eprint/3411 |
Actions (login required)
![]() |
View Item |