ANALISA SISTEM PROTEKSI GENERATOR 26,6 MVA DENGAN MENGGUNAKAN RELAY DIFFERENSIAL DI PT PUPUK SRIWIDJAJA PALEMBANG (PUSRI 1B)

MUHAMMAD, REZA PAHLEPI (2016) ANALISA SISTEM PROTEKSI GENERATOR 26,6 MVA DENGAN MENGGUNAKAN RELAY DIFFERENSIAL DI PT PUPUK SRIWIDJAJA PALEMBANG (PUSRI 1B). Other thesis, POLITEKNIK NEGERI SRIWIJAYA.

[img]
Preview
Text
I. COVER.pdf

Download (60kB) | Preview
[img]
Preview
Text
II. BAB I.pdf

Download (16kB) | Preview
[img]
Preview
Text
III. BAB II.pdf

Download (2MB) | Preview
[img] Text (BAB III Metodologi Penelitian)
IV. BAB III.pdf
Restricted to Repository staff only

Download (355kB)
[img] Text (BAB IV Pembahasan)
V. BAB IV.pdf
Restricted to Repository staff only

Download (151kB)
[img]
Preview
Text
VI. BAB V.pdf

Download (20kB) | Preview
[img]
Preview
Text
VII. DAFTAR PUSTAKA.pdf

Download (7kB) | Preview

Abstract

In an industry that uses a generator as a device to produce electrical energy, surely needs a seat on the generator. Disturbance in the generator may interfere with the operation of power generation systems. Therefore, in a generator at the plant of course equipped with protective devices to protect the generator in order to avoid unwanted interference. One of them is to use a differential relay. Differential relay is a protection tool that can protect interference in the stator coil generator is based on a balance which is the ratio of current flowing on both sides of the stator coil generator through the intermediary of a current transformer (CT). Pusri 1B in the setting current value on the CT is 3.21 A and pickup current value on the CT is 2.93 A. For CT nominal current has value of 2.79 A. Meanwhile, the actual current of the highest in CT is at a value of 1.8 A and lowest worth 1.625 A. Thus, the differential current is smaller than the current setting (Idif < Iset), it means that the generator is in a state of normal or no interference. In addition, the power consumption of the generator does not reach 60% in Pusri 1B is not economical. But it is aimed to keep the equipment in order to secure and mitigate the risk of loss due to damage of the equipment.

Item Type: Thesis (Other)
Uncontrolled Keywords: Generator, Relay Differensial, dan Transformator Arus (CT)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Electrical Engineering > Undergraduate Theses
Depositing User: Mrs Trisni Handayani
Date Deposited: 31 Jul 2017 06:41
Last Modified: 31 Jul 2017 06:41
URI: http://eprints.polsri.ac.id/id/eprint/3817

Actions (login required)

View Item View Item