PERHITUNGAN RUGI ENERGI LISTRIK PADA JARINGAN DISTRIBUSI DI PT PLN (PERSERO) WS2JB Cab. PALEMBANG RAYON SUKARAMI

BUDIMANSYAH, AKBAR (2017) PERHITUNGAN RUGI ENERGI LISTRIK PADA JARINGAN DISTRIBUSI DI PT PLN (PERSERO) WS2JB Cab. PALEMBANG RAYON SUKARAMI. Other thesis, POLITEKNIK NEGERI SRIWIJAYA.

[img]
Preview
Text
COVER, Lembar Pengesahan, Motto, Kata Pengantar, Abtrak, Daftar isi.pdf

Download (277kB) | Preview
[img]
Preview
Text
Bab 1.pdf

Download (225kB) | Preview
[img]
Preview
Text
Bab 2.pdf

Download (917kB) | Preview
[img] Text (BAB III Metode Penelitian)
Bab 3.pdf
Restricted to Repository staff only

Download (229kB) | Request a copy
[img] Text (BAB IV Hasil dan Pembahasan)
Bab 4.pdf
Restricted to Repository staff only

Download (271kB) | Request a copy
[img]
Preview
Text (BAB V Kesimpulan dan Saran)
Bab 5.pdf

Download (114kB) | Preview
[img]
Preview
Text
Daftar pustaka.pdf

Download (9kB) | Preview

Abstract

Distribution shaft works to convert medium voltage (12kV or 20kV) into low voltage (220 volt and 380 volt) and distribute power to low voltage consumer. It can be generally stated that in a transformer there are two types of losses, ie without load and full load losses. Transformer is an electric machine that plays an important role in the distribution system. The transform transformer transforms the intermediate voltage into a low voltage. As with other components of the distribution circuit, the energy losses and voltage drops caused by the electric current flowing to the load are the determinations for the selection and location of the transformer At Rayon Sukarami the network system used is a radial network system. This network is used for small and medium load areas with low density and relatively fixed. Viewed from the point of circuit and its security system, this form of network is simple, and cheap so that its reliability is less good. In the calculation of the loss of electrical energy in the distribution network, PT PLN has its own formula. To be able to calculate the loss of electrical energy, it takes the energy data received from, (1) UPT, (2) MUSI II, (3) Kenten, (4) Mariana. The unit or sector that receives energy from all four places is Kenten, in addition to the data obtained is KWH Sold or electric energy sold at KWH Selling Tul III-09. In the distribution section there is also own use untu distribution unit (PS Distribution). Of all the results obtained, the authors concluded that, the delivery of power is only done to the Kenten sector, because the delivery to Rivai and Mariana only 0 Kwh, as well as in the acceptance of energy sector Rivai who do not accept. The second conclusion, seen from the data in the can during the last four months of sending energy and receiving energy has increased except in February

Item Type: Thesis (Other)
Uncontrolled Keywords: Jaringan distribusi
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Electrical Engineering > Undergraduate Theses
Depositing User: Mrs Trisni Handayani
Date Deposited: 19 Apr 2018 08:35
Last Modified: 19 Apr 2018 08:35
URI: http://eprints.polsri.ac.id/id/eprint/4455

Actions (login required)

View Item View Item