LESTARI, AYU (2019) ANALISA TAHANAN PENTANAHAN TRANSFORMATOR DAYA 80 MVA MENGGUNAKAN MATLAB GUI DI PLTU BUKIT ASAM. Other thesis, POLITEKNIK NEGERI SRIWIJAYA.
|
Text (COVER)
File I.pdf Download (380kB) | Preview |
|
|
Text
BAB I.pdf Download (295kB) | Preview |
|
|
Text
BAB II.pdf Download (1MB) | Preview |
|
![]() |
Text
BAB III.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
![]() |
Text
BAB IV.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
|
Text
BAB V.pdf Download (201kB) | Preview |
|
|
Text
DAFTAR PUSTAKA.pdf Download (63kB) | Preview |
Abstract
UntukmendapatkannilaitahananpentanahanTransformatorDaya 80 MVA di PLTU Bukit AsamdilakukanpengukuranlangsungdenganmenggunakanKYORITSU Digital Earth Tester Model 4105A. Untukhasilpengukuransecaralangsungdidapathasil rata- rata nilaitahananpentanahansebesar 0,20 Ω, laludariperhitungan manual didapatnilaitahananpentanahanempatpasakelektrodasebesar 0,64 Ω. SedangkanperhitunganmenggunakMatlab Graphical User Interface (GUI) nilai rata-rata tahananpentanahansebesar 0,206667 Ω, nilaitahananempatpasakparalelsebesar 0,645562 Ω.Jadidarihasilpengukuranlangsung ,perhitungan manual danmenggunakanMatlab Graphical User Interface (GUI), nilaitahananpentanahanmasihmemenuhistandarPersyaratanUmumInstalasiListrik (PUIL), yaitukurangdari 5 Ω. Agar nilaitahananpentanahantidakmengalamiperubahansebaiknyadilakukanpemeliharaandanpengukurannilaitahananpentanahansecaraberkala.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | TahananPentanahan, TransformatorDaya, Matlab Graphical User Interface (GUI), |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering > Undergraduate Theses |
Depositing User: | Mr Bambang Anthony |
Date Deposited: | 23 Aug 2021 01:24 |
Last Modified: | 23 Aug 2021 01:24 |
URI: | http://eprints.polsri.ac.id/id/eprint/8267 |
Actions (login required)
![]() |
View Item |