Bow, Yohandri and Meidinariasty, Anerasari and Rusdianasari and Rusnadi, Irawan and Fuadi, A. Lutfi (2019) Treatment of Leachate from Garbage using Electrocoagulation Type MP-P (MonoPolar-Paralel) Methode. IOP Conference Series: Journal of Physics. pp. 1-7. ISSN 1742-6596
Full text not available from this repository.Abstract
Leachate water is a very dangerous liquid due to its organic and inorganic content that can pollute water body around the landfill, hence treatment is needed. Electrocoagulation is one of the methods that can be used. The research aims to determine a characteristic of leachate water at TPA Sukawinatan (COD, pH, BOD 5, TSS, and Cd content), the effect to electrodes distance (aluminium anode and iron cathode) and optimum time of treatment Leachate Water using electrocoagulation type MP-P (MonoPolar-Parallel) method. The electrical potential was set at 12 volts and time variations of 30,60,75, 90 and 120 minutes and electrodes distances of 6, 7 and 8 cm. The result obtained shown that COD decreased to 529.20 mg/L, pH became 8.34, BOD 5 decreased to 17.6 mg/L, TSS became 108 mg/L and <0.0015 mg/L of Cd content. The optimum electrodes distance to treat leachate water was found 8 cm in 120 minutes fo electrocoagulation type MP-P.
Item Type: | Article |
---|---|
Subjects: | T Technology > TP Chemical technology |
Divisions: | Chemical Engineering > Proceeding and Seminar |
Depositing User: | Mrs Trisni Handayani |
Date Deposited: | 01 May 2023 14:55 |
Last Modified: | 23 May 2023 08:36 |
URI: | http://eprints.polsri.ac.id/id/eprint/13406 |
Actions (login required)
![]() |
View Item |