PENGARUH ARUS NETRAL DAN BEBAN LEBIH TRAFO DAYA DISTRIBUSI PRIMER 20 KV PADA PENYULANG KENARI YANG DISUPLAI DARI GI SEDUDUK PUTIH

PRATAMA, MUHAMMAD ANTHONY (2017) PENGARUH ARUS NETRAL DAN BEBAN LEBIH TRAFO DAYA DISTRIBUSI PRIMER 20 KV PADA PENYULANG KENARI YANG DISUPLAI DARI GI SEDUDUK PUTIH. Other thesis, POLITEKNIK NEGERI SRIWIJAYA.

[img]
Preview
Text (Cover)
FILE I.pdf

Download (706kB) | Preview
[img]
Preview
Text (BAB I Pendahuluan)
FILE II.pdf

Download (215kB) | Preview
[img]
Preview
Text (BAB II Tinjauan Pustaka)
FILE III.pdf

Download (1MB) | Preview
[img] Text (BAB III Metodologi Penelitian)
FILE IV.pdf
Restricted to Repository staff only

Download (232kB) | Request a copy
[img] Text (BAB IV Pembahasan)
FILE V.pdf
Restricted to Repository staff only

Download (571kB) | Request a copy
[img]
Preview
Text (BAB V Kesimpulan dan saran)
FILE VI.pdf

Download (162kB) | Preview

Abstract

Objective analysis of the effect of current titles Flow Effect Of Neutral And Expenses Losses Transformer Because Of Unbalanced Load On GI Seduduk Putih At Kenari’s Feeder is to know the value of the neutral current transformer substation distribution caused by load imbalance, knowing the magnitude of losses or losses arising from the neutral current , determine the percentage of load imbalance in distribution substations and compare the magnitude of losses at each substation due to the current in the neutral conductor of the transformer. Analysis of the load imbalance is done by comparing the data of loading transformer in the afternoon and evening at 3 distribution substations which I.283, I.346, I.533, based on data taken directly by measuring the current at substation. After analysis, it was found that most of the load imbalance during most of the day at each substation occurred in I.533 (17%), then the neutral current emerging (66 A), and losses due to neutral current flowing into the ground greater (13.18%). While most of the load imbalance on the biggest night on the evening occurred on I. 346 (32%), then the neutral current emerging (62 A), and losses due to neutral current flowing to ground the greater (4.68%).

Item Type: Thesis (Other)
Uncontrolled Keywords: Ketidakseimbangan, Arus Netral, Rugi-Rugi, Transformator
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Electrical Engineering > Undergraduate Theses
Depositing User: Mrs Trisni Handayani
Date Deposited: 23 Apr 2018 03:25
Last Modified: 23 Apr 2018 03:25
URI: http://eprints.polsri.ac.id/id/eprint/4471