INSPEKSI PEMUTUS TENAGA (PMT) PADA MOTOR BOILER FEED WATER PUMP DI PLTGU KERAMASAN

HARTA, HENGKI JUNI (2019) INSPEKSI PEMUTUS TENAGA (PMT) PADA MOTOR BOILER FEED WATER PUMP DI PLTGU KERAMASAN. Other thesis, POLITEKNIK NEGERI SRIWIJAYA.

[img]
Preview
Text
COVER.pdf

Download (262kB) | Preview
[img]
Preview
Text (BAB I PENDAHULUAN)
BAB I.pdf

Download (267kB) | Preview
[img]
Preview
Text (BAB II TINJAUAN PUSTAKA)
BAB II.pdf

Download (716kB) | Preview
[img] Text (BAB III METODOLOGI PENELITIAN)
BAB III.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] Text (BAB IV PEMBAHASAN)
BAB IV.pdf
Restricted to Repository staff only

Download (347kB) | Request a copy
[img]
Preview
Text (BAB V KESIMPULAN DAN SARAN)
BAB V.pdf

Download (184kB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf

Download (85kB) | Preview

Abstract

Berdasarkan hasil pembahasan inspeksi pemutus tenaga (PMT) pada motor boiler feed water pump di PLTGU Keramasan Palembang, nilai resistansi yang di dapat dari hasil pengukuran tahanan kontak, tahanan isolasi, dan keserempakan masih dalam kondisi wajar, karena telah melebihi nilai yang diijinkan yaitu R > 6,3 Mega ohm / 6,3 KV untuk tahan isolasi,50 Micro ohm untuk tahanan kontak, dan perbedaan waktu (∆t) tidak boleh melebihi dari 10 msuntuk pengujian keserempakan. Inspeksi pada PMT sangatlah penting karena jika PMT tidak diinspeksi secara rutin maka kerja PMT tidak efisien dan akan menyebabkan kerusakan pada PMT tersebut.

Item Type: Thesis (Other)
Uncontrolled Keywords: : Inspeksi, Nilai Resistansi, Pemutus Tenaga (PMT).
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Electrical Engineering > Undergraduate Theses
Depositing User: Mr Bambang Anthony
Date Deposited: 23 Aug 2021 00:41
Last Modified: 23 Aug 2021 00:45
URI: http://eprints.polsri.ac.id/id/eprint/8168

Actions (login required)

View Item View Item