PENGOLAHAN AIR SUMUR MENJADI AIR SIAP MINUM MELALUI PROSES REVERSE OSMOSIS

Ramdyasari, Intan (2014) PENGOLAHAN AIR SUMUR MENJADI AIR SIAP MINUM MELALUI PROSES REVERSE OSMOSIS. Other thesis, Politeknik Negeri Sriwijaya.

[img]
Preview
Text (COVER)
Cover.pdf

Download (423kB) | Preview
[img]
Preview
Text (BAB I PENDAHULUAN)
BAB_I.pdf

Download (94kB) | Preview
[img]
Preview
Text (BAB II TINJAUAN PUSTAKA)
BAB_II.pdf

Download (311kB) | Preview
[img] Text (BAB III METODELOGI PENELITIAN)
BAB_III.pdf
Restricted to Repository staff only

Download (436kB)
[img] Text (BAB IV HASIL DAN PEMBAHASAN)
BAB_IV.pdf
Restricted to Repository staff only

Download (165kB)
[img]
Preview
Text (BAB V KESIMPULAN DAN SARAN)
BAB_V.pdf

Download (88kB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
Daftar_Pustaka.pdf

Download (95kB) | Preview
[img]
Preview
Text (LAMPIRAN I)
LAMPIRAN I.pdf

Download (164kB) | Preview
[img]
Preview
Text (LAMPIRAN II)
LAMPIRAN II.pdf

Download (114kB) | Preview
[img]
Preview
Text (LAMPIRAN III)
LAMPIRAN III.pdf

Download (706kB) | Preview

Abstract

WELL’S WATER TREATMENT FOR DRINKING WATER THROUGH THE REVERSE OSMOSIS PROCESS ( Intan Ramdyasari, 2014, 67 Pages, 7 Table, 2 Picture, 4 Attachment ) Water is a primary need of living because water is one of important role in life processes. The quality of raw water from various sources have quality and quantity of the different characteristics, which means not all areas obtain clean water supply that can be processed into potable water in accordance with the qualified clean water standards of clean water. Therefore, this study was designed tool for reverse osmosis water treatment taps into drinkable water in order to remove the metal content, organic substances and bacteria according to standard drinking water of quality standard Ministry of Health of the Republic of Indonesian. The stages in this study is a preliminary analysis of samples and test after reverse osmosis membrane device with parameters of physics, chemistry and biology. Physical parameters on test analysis of drinking water, such as temperature, color, turbidity, dissolved solids (TDS), smell and taste. In the analysis of test chemical parameters of drinking water, such as pH, hardness, chloride, organic substances, ammonia, sulfate, nitrite, nitrate, chromium, cadmium, iron, manganese, copper, aluminum, zinc and lead. While on the biology test parameters analysis includes the analysis of the E-Coli bacteria. For the test results of water quality analysis tools have proven reverse osmosis membrane according to standard ISO quality drinking water of each parameter analysis performed. Keywords: Reverse Osmosis, Water, Water Parameters

Item Type: Thesis (Other)
Uncontrolled Keywords: Reverse Osmosis, Water, Water Parameters
Subjects: T Technology > TP Chemical technology
Divisions: Chemical Engineering > Undergraduate Theses
Depositing User: Mrs Trisni Handayani
Date Deposited: 18 Jan 2016 02:56
Last Modified: 18 Jan 2016 02:56
URI: http://eprints.polsri.ac.id/id/eprint/949

Actions (login required)

View Item View Item