PERENCANAAN PEMBANGUNAN GEDUNG RUMAH TOKO (RUKO) KENTEN MAS PALEMBANG

SATRIYO WICAKSONO, DIMAS and ROYHAN, MUHAMMAD (2014) PERENCANAAN PEMBANGUNAN GEDUNG RUMAH TOKO (RUKO) KENTEN MAS PALEMBANG. Other thesis, Politeknik Negeri Sriwijaya.

[img]
Preview
Text (Cover)
1. Cover.pdf

Download (138kB)
[img] Text (BAB I PENDAHULUAN)
2. BAB I.pdf

Download (30kB)
[img]
Preview
Text (BAB II LANDASAN TEORI)
3. BAB II.pdf

Download (267kB) | Preview
[img] Text (BAB III PERHITUNGAN KONSTRUKSI)
4. BAB III.pdf
Restricted to Repository staff only

Download (2MB)
[img] Text (BAB IV PENGELOLAAN PROYEK)
5. BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[img]
Preview
Text (BAB V PENUTUP)
6. BAB V.pdf

Download (14kB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
7. Daftar Pustaka.pdf

Download (7kB) | Preview
[img] Other (Thumbnails conversion from text to thumbnail_medium)
medium.jpg

Download (0B)

Abstract

The final report titled “development planning gedung house store ( shophouse ) kenten mas palembang”. The purpose of the final report this is to plan and take into account the planning of the building structures shop-house. In doing this planning data obtained from documentation and analysis of this use sni poles no 03-2847-2002 “procedures of reckoning structure concrete to building“. Regulation encumbering indonesa to the 1983. Calculation planning covering calculation of the building structures consisting of reckoning thick bony plates, the size of a beam and column. While calculation structure, covering plate a ladder, the beam, a column sloof and legs. To project management plan covering specifications ( rks ), and the terms of a list of wage labor, a listing of prices of the material, nwp, barchart, and the curves ' S. Planning structures using the quality of concrete Fc’ 25 MPa, and the quality of steel fy 400 MPa, The size of the dimensions of a column 25x40 cm with long landscapes maximum 5.5 m, girder 25x40 cm, with size thick plate a roof 11 cm and thick plate 12 cm, the floor a measure of sloof 25x40 cm with the foundation of m. tread the depth of 2 m. On the basis of calculations, writer can be concluded that in plotting data and pictures must complete and calculation should be accurate to structure safe and enforceable development of building houses the store.

Item Type: Thesis (Other)
Uncontrolled Keywords: On the basis of calculations, writer can be concluded that in plotting data and pictures must complete and calculation should be accurate to structure safe and enforceable development of building houses the store.
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Civil Engineering > Undergraduate Theses
Depositing User: Mr Bambang Anthony
Date Deposited: 18 Nov 2015 08:53
Last Modified: 18 Nov 2015 08:53
URI: http://eprints.polsri.ac.id/id/eprint/1368

Actions (login required)