INDEKS POLARISASI ( IP ) TAHANAN ISOLASI TRANSFORMATOR 30 MVA DI GARDU INDUK BUKIT SIGUNTANG PT.PLN (PERSERO)

Gumay, Agatha Lusia Darosza (2015) INDEKS POLARISASI ( IP ) TAHANAN ISOLASI TRANSFORMATOR 30 MVA DI GARDU INDUK BUKIT SIGUNTANG PT.PLN (PERSERO). Other thesis, Politeknik Negeri Sriwijaya.

Full text not available from this repository.

Abstract

Testing in the maintenance of transformers one of which is in the form of Prisoners testing insulation and Polarization Index. Measurements were taken at each winding directly to the ground using a megger. So from this test can be calculated that the value of Polarization Index measurement for 10 minutes compared with the results of insulation resistance measurement 1 minute. Polarization Index is an indication of dryness and cleanliness of the coils. Writer wanted to know how much influence the polarization index value that results will determine whether the equipment is safe to operate. Based on the results of the discussion about the value of polarization index 3 power transformer 30 MVA 70/20 kV at substation Bukit Siguntang PT.PLN (Persero) Palembang, it appears that the average value of polarization index before maintenance was 2.92 shows that the transformer is in good condition, and the average value of IP - 3 after average transformers at substation Bukit Siguntang is very good 4.12. Namely the transformer windings after cleaning increased 1.2. The increasing age of the transformer if it is not done, the maintenance of transformer Polarization Index value will decline. Keywords: Insulation Resistance, Polarization Index, Transformers

Item Type: Thesis (Other)
Uncontrolled Keywords: Arismunandar, A. Kuwahara. 1978.Teknik Tenaga Listrik Jilid I. PT. Pradnya : Jakarta. https://lman.weebly.com/uploads/1/5/7/2/15720440/transformator.doc, diakses pada hari Senin tanggal 06 April 2015 pukul 19:23 WIB. https://syuratman.files.wordpress.com/2011/10/bab-iii-study-kasus.doc, diakses pada hari Selasa tanggal 07 April 2015 pukul 20:23 WIB. https://power-grounding.blogspot.com/2009/11/pengujian-tahanan-isolasi sebagai.html, diakses pada hari Selasa tanggal 07 April 2015 pukul 21:12 WIB. IEEE C57.125-1991 “ Guide for Failure Investigation, Documentation, and Analysis for Power Transformers and Shunt Reactors ”. Kadir, Abdul. 2006. Distribusi dan Utilisasi Tenaga Listrik. Universitas Indonesia: Jakarta. Marsudi, Djiteng. 2011. Pembangkitan Energi Listrik Edisi Kedua. Erlangga : Jakarta. PT. PLN (PERSERO). Buku Pedoman Batasan Operasi dan Pemeliharaan Peralatan Penyaluran Tenaga Listrik Trafo Tenaga. SK114 No 1 – 22 /HARLUR-PST/2009. Perusahaan Listrik Negara. Indonesia. Teknik Pengendalian Instrumen Logam, Jilid II Kementrian Pendidikan dan Kebudayaan Republik Indonesia, 2013. Tobing, Bonggas L. 2003. Dasar – dasar Teknik Pengujian Tegangan Tinggi Edisi Kedua. Erlangga : Jakarta. Tobing, Bonggas L. 2012. Peralatan Tegangan Tinggi Edisi Kedua. Erlangga : Jakarta.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Electrical Engineering > Undergraduate Theses