EVALUASI DISTRIBUSI TEGANGAN RENDAH PADA GARDU DISTRIBUSI PT. PLN (PERSERO) RAYON MARIANA

Mirwan Setiawan, Muhammad (2014) EVALUASI DISTRIBUSI TEGANGAN RENDAH PADA GARDU DISTRIBUSI PT. PLN (PERSERO) RAYON MARIANA. Other thesis, Politeknik Negeri Sriwijaya.

[img]
Preview
Text (Cover)
COVER.pdf

Download (85kB) | Preview
[img]
Preview
Text (BAB I PENDAHULUAN)
BAB I.pdf

Download (30kB) | Preview
[img]
Preview
Text (BAB II TINJAUAN PUSTAKA)
BAB II.pdf

Download (299kB) | Preview
[img] Text (BAB III KEADAAN UMUM)
BAB III.pdf
Restricted to Repository staff only

Download (164kB)
[img] Text (BAB IV PEMBAHASAN)
BAB IV.pdf
Restricted to Repository staff only

Download (347kB)
[img]
Preview
Text (BAB V KESIMPULAN DAN SARAN)
BAB V.pdf

Download (25kB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf

Download (6kB) | Preview

Abstract

In secondary distribution network of electrical power distribution system, the voltage up to the customer is often lower than standard voltages which specified by PLN. This is caused by the drop voltage in the conductor while doing an electrical distribution. Some causes of this excessive amount of drop voltage are the flowing current on conductor, conductor’s length, and the type of used conductor. These three factors are not only causing a great value of drop voltage, but also power losses in conductor itself. This final report shows the result of losses and drop voltage evaluation in each phase of M-184 distribution substation of PT. PLN (Persero) Rayon Mariana. Based on evaluation results, the flowing current on conductor is the major cause of power losses. This can be seen on A branch which has shorter length than B branch, however it has more power losses than A branch. This evaluation also show that PLN have to bear 29,887 kW of power losses. At the same time, drop voltage on A, B, and D branch have already exceeded the standards of PLN, i.e. over than 4%. To overcome these problems, requiring the addition of new network at M- 184 distribution substation. With this addition, most of attached load can be replaced to a new network, so that we can decrease the amount of flowing current in conductor to improve the quality of electrical distribution. Keywords : Power losses, Drop voltage.

Item Type: Thesis (Other)
Uncontrolled Keywords: Power losses, Drop voltage.
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Telecommunication Engineering > Undergraduate Theses